Intuitive and Versatile Display: Suitable for various industries including petroleum, chemicals, and electric power, capable of measuring corrosive media.
Remote Monitoring Capability: Optional liquid level transmitters allow for remote transmission and monitoring of liquid level signals.
Safety and Reliability: Designed with a simple structure for easy maintenance, it is safe for use in flammable and explosive environments, ensuring secure production.
▋ Product Description
The magnetic flip plate level meter is a field level meter with the float as the measuring element and the magnetic flip plate (magnetic flip column) as the display element. It can realize alarm, chain, remote monitoring and other functions by selecting upper and lower limit switches and liquid level transmitters. It is widely used for liquid level measurement and control in the production process of electric power, petroleum, chemical industry, metallurgy, environmental protection, shipbuilding, construction, food and other industries.
▋ Product Parameter
Parameter | Details |
Measurement Range | Water:20°C (25-100000/h);Air:0.1MPa,20℃ (0.7-1800m/h) |
Precision | ±10mm |
Turndown Ratio | Standard Type 10:1 |
Media Density | 0.45~2.0g/cm³ |
Accuracy Class | Standard RemoteType 1.5 |
Working Pressure | -0.1~32MPa |
InstrumentCaliber | Standard Type DN15-DN100 |
Working Temperature | -38°C-530℃ |
Pressure Rating | Standard Type DN15-DN50/PN4.0MPa;DN80-DN100/PN1.6MPa |
▋ Installation Method
1. Vertical Installation: The level gauge should be installed vertically in a location that is easily accessible for observationand operation by the field operator. A sealing gasket should be placed on the flange's mating surface, and all component screws should be securely tightened.
2. Support Measures: If the tube is excessively long and exhibits a certain degree of deflection, appropriate support should be provided to the tube.
3. Pressure Testing: When installing the level gauge on a pressure vessel, it should undergo pressure testing together with the vessel to ensure there are no leaks before it is put into operation.
4. Medium Flow: When the instrument is ready for operation, the upper valve should be opened first, followed by slowly opening the lower valve to allow the medium to flow into the float chamber gradually.
▋ Application
Widely used in electric power, petroleum, chemical, metallurgy, environmental protection, shipbuilding, construction, food and other industries in the production process of liquid level measurement and control.
▋ FAQ
Q: How does a magnetic flip-board level gauge work?
A: It operates on the buoyancy principle. As the liquid level changes, the float moves up or down, causing magnetic columns to flip and indicate the current level.
Q: What is the installation process?
A: The gauge should be installed vertically. Ensure flanges are properly sealed and, if the measuring tube is long, provide adequate support. Conduct a leak test before operation.
Q: In what scenarios is it applicable?
A: It's suitable for various applications such as storage tanks, reactors, and any other situation requiring liquid level monitoring.
Q: Can it be used in flammable or explosive environments?
A: Yes, but an explosion-proof version should be selected. Follow all safety guidelines and ensure the equipment is grounded.
Q: How do I calibrate the level gauge?
A: Regularly compare it with a known accurate standard. If discrepancies are found, adjust or contact the manufacturer for assistance.